UNIVERSAL
SIDE ACCESS
HOUSING (USAH)
:
◎ June’s USAH system offers all the advantages of a conventional side access housing unit: total flexibility in the selection and combination of particulate filter elements, more productive use of mechanical space, greater ease of servicing, reduced maintenance costs, more enhanced air quality.。
◎ Maximum versatility in the selection of gas phase filter elements allows the designer to choose among a broad range of specially-formulated Chemical-cleansing filter media and the right combination of gas phase filter elements to meet the precise needs of each installation.
◎ June’s USAH System offers total design flexibility for the control of particulate contaminants as well as gaseous contaminants.
◎ COMPLETELY FACTORY ASSEMBLED
The USAH is shipped ready to be installed. No field assembly is required.
◎ RUGGED CONSTRUCTION
Fabricated of 1.0 stainless steel and PU panel, standard housing features a Penta-Post frame design reinforced by a sturdy U-channel base for structural rigidity and maximum operating life.
◎ FILTER MOUNTING TRACK
The USAH features an stainless steel filter mounting track incorporating a nylon pile seal to prevent air bypass. A wide variety of optional tracking sizes makes it possible to accept virtually any specified configuration of filter elements within the unit.
◎ SIZE FLEXIBILITY
A wide range of available sizes allows the USAH to be tailored to the needs of a customer’s air handling system, regardless of the system capacity.
◎ GASEOUS FILTRATION MODULES
Media modules are constructed of 1.0mm perforated stainless steel. Each removable module includes quick-release access plates which require no service tools.
◎ SEALING INTEGRITY
Positive seal is accomplished by providing neoprene foam seals on all doors, nylon pile seals on media filter tracks and leak-proof silicone sealant on all mating joints.
◎ EASY MAITENANCE
Heavy-duty side access doors employ quick release latches to facilitate filter inspection and change out.
◎ TECH-CHEK SERVICE
Regular laboratory analysis of Chemical-cleansing media samples (forwarded by the owner) is provided at no extra charge to establish precise media life cycles.
 |
|
 |
☆ For more details, please CONTACT JUNE, or DOWN LOAD the PDF files.
TYPICAL FILTER COMBINATIONS (examples)
STAGE |
COMPONENTS |
COMMERCIALOFFICEBUILDING |
HOSPITAL |
PULP & PAPER MILL |
1 |
30% preliminary particulate filter |
30% preliminary particulate filter |
30% preliminary
particulate filter |
2 |
90% intermediate
particulate filter |
90% intermediate particulate filter-12" |
90% intermediate
particulate filter |
3 |
CM-1000 gas phase media |
CM-1000 gas phase media |
CM-9000 gas phase media |
4 |
CM-3000 gas ppase media |
CM-3000 gas ppase media |
CM-1000 gas ppase media |
5 |
30% final particulate filter |
30% final particulate filter |
30% final particulate filter |
6 |
|
99.9% absolute
filter-12" |
|
Actual filter combinations can be provided upon request.
TABLE 1: DIMESIONS -MODELD USAH
MODEL |
AIR FLOW |
A |
B |
two stages
|
D |
E |
WEIGHT |
CMF |
M3/HR |
in |
mm |
in |
mm |
in |
mm |
in |
mm |
in |
mm |
lb |
kg |
102 |
1000 |
1700 |
26 |
660 |
18 |
457 |
72 |
1829 |
22 |
559 |
14 |
356 |
340 |
154 |
104 |
2000 |
3400 |
50 |
1270 |
18 |
457 |
72 |
1829 |
46 |
1168 |
14 |
356 |
650 |
295 |
202 |
2000 |
3400 |
26 |
660 |
30 |
762 |
72 |
1829 |
22 |
559 |
26 |
660 |
600 |
272 |
204 |
4000 |
6800 |
50 |
1270 |
30 |
762 |
72 |
1829 |
46 |
1168 |
26 |
660 |
1100 |
499 |
402 |
4000 |
6800 |
26 |
660 |
54 |
1372 |
72 |
1829 |
22 |
559 |
50 |
1270 |
1100 |
499 |
404 |
8000 |
13600 |
50 |
1270 |
54 |
1372 |
72 |
1829 |
46 |
1168 |
50 |
1270 |
2100 |
953 |
406 |
12000 |
20400 |
74 |
1880 |
54 |
1372 |
72 |
1829 |
70 |
1778 |
50 |
1270 |
3100 |
1407 |
408 |
16000 |
27200 |
98 |
2489 |
54 |
1372 |
72 |
1829 |
94 |
2388 |
50 |
1270 |
4050 |
1839 |
604 |
12000 |
20400 |
50 |
1270 |
78 |
1981 |
72 |
1829 |
46 |
1168 |
74 |
1880 |
3100 |
1407 |
606 |
18000 |
30600 |
74 |
1880 |
78 |
1981 |
72 |
1829 |
70 |
1778 |
74 |
1880 |
4550 |
2066 |
The Unit weights do not include media. Media weight can be calculated in according to table 2.
Note: All dimensions are approximate. Select multiple units above these sizes or contact JUNE for special components, applications or capacities.
SEQUENCE: 1 2P Pre-filter section
2 12P Intermediate filter section-cell type
3 18M Filter section –Chemical-cleansing -1st stage
4 18M Filter section-Chemical-cleansing-2nd stage
5 2P After filter section- V typer
6 Filter gauges (DPMS)
TABLE 2:USAH MEDIA VOLUME |
MODEL |
QUANTITIES PER STAGE |
MM-18 MODULES |
MM-18 MEDIA
|
MM-12D MODULES
|
MM-12D MEDIA
|
Cu.ft. |
Liter |
Cu.ft. |
Liter |
102 |
2 |
2 |
57 |
1 |
1 |
28 |
104 |
4 |
3 |
85 |
2 |
2 |
57 |
106 |
6 |
4 |
113 |
3 |
3 |
85 |
108 |
8 |
5 |
142 |
4 |
4 |
113 |
202 |
4 |
3 |
85 |
2 |
2 |
57 |
204 |
8 |
5 |
142 |
4 |
4 |
113 |
206 |
12 |
8 |
226 |
6 |
6 |
170 |
208 |
16 |
10 |
283 |
8 |
8 |
226 |
302 |
6 |
4 |
113 |
3 |
3 |
85 |
304 |
12 |
8 |
226 |
6 |
6 |
170 |
306 |
18 |
11 |
311 |
9 |
9 |
255 |
308 |
24 |
15 |
425 |
12 |
12 |
340 |
402 |
8 |
5 |
142 |
4 |
4 |
113 |
404 |
16 |
10 |
283 |
8 |
8 |
226 |
406 |
24 |
15 |
425 |
12 |
12 |
340 |
408 |
32 |
20 |
566 |
16 |
16 |
453 |
502 |
10 |
6 |
170 |
5 |
5 |
142 |
504 |
20 |
12 |
340 |
10 |
10 |
283 |
506 |
30 |
18 |
509 |
15 |
15 |
425 |
508 |
40 |
24 |
679 |
20 |
20 |
566 |
602 |
12 |
8 |
226 |
6 |
6 |
170 |
604 |
24 |
15 |
425 |
12 |
12 |
340 |
606 |
36 |
22 |
623 |
18 |
18 |
509 |
608 |
48 |
29 |
821 |
24 |
24 |
679 |
Media Weight = [Density of Media] xVolume xNo. of Stages
Densities: CM-1000 = 50 lb./ft3(800 kg/m3)
CM-3000 = 30 lb./ft3(480 kg/m3)
CM-7000 = 45 lb./ft3(720 kg/m3)
CM-9000 = 36 lb./ft3(576 kg/m3)
TABLE 3:USAH UNIT SIZE VS CFM'S BASED ON VARIOUS VELOCITIES
USAH UNIT SIZE VS CFM'S BASED ON VARIOUS VELOCITIES |
MODEL |
250FPM |
373FPM |
500FPM |
CFM |
m3/hr |
CFM |
m3/hr |
CFM |
m3/hr |
102 |
500 |
850 |
750 |
1275 |
1000 |
1700 |
104 |
1000 |
1700 |
1500 |
2550 |
2000 |
3400 |
106 |
1500 |
2550 |
2250 |
3825 |
3000 |
5100 |
108 |
2000 |
3400 |
3000 |
5100 |
4000 |
6800 |
202 |
1000 |
1700 |
1500 |
2550 |
2000 |
3400 |
204 |
2000 |
3400 |
3000 |
5100 |
4000 |
6800 |
206 |
3000 |
5100 |
4500 |
7650 |
6000 |
10200 |
208 |
4000 |
6800 |
6000 |
10200 |
8000 |
13600 |
302 |
1500 |
2550 |
2250 |
3825 |
3000 |
5100 |
304 |
3000 |
5100 |
4500 |
7650 |
6000 |
10200 |
306 |
4500 |
7650 |
6750 |
11475 |
9000 |
15300 |
308 |
6000 |
10200 |
9000 |
15300 |
12000 |
20400 |
402 |
2000 |
3400 |
3000 |
5100 |
4000 |
6800 |
404 |
4000 |
6800 |
6000 |
10200 |
8000 |
13600 |
406 |
6000 |
10200 |
9000 |
15300 |
12000 |
20400 |
408 |
8000 |
13600 |
12000 |
20400 |
16000 |
27200 |
502 |
2500 |
4250 |
3750 |
6375 |
5000 |
8500 |
504 |
5000 |
8500 |
7500 |
12750 |
10000 |
17000 |
506 |
7500 |
12750 |
11250 |
19125 |
15000 |
25500 |
508 |
10000 |
17000 |
15000 |
25500 |
20000 |
34000 |
602 |
3000 |
5100 |
4500 |
7650 |
6000 |
10200 |
604 |
6000 |
10200 |
9000 |
15300 |
12000 |
20400 |
606 |
9000 |
15300 |
13500 |
22950 |
18000 |
30600 |
608 |
12000 |
20400 |
18000 |
30600 |
24000 |
40800 |
808 |
16000 |
27200 |
24000 |
40800 |
32000 |
54400 |
TABLE 4:USAH STATIC PRESSURE CALCULATIONS
FILRATION |
FILTER STATIC PRESSURES @ VARIOUS FPM |
TYPE |
MODEL NO. |
150FPM |
200 FPM |
250 FPM |
300 FPM |
400 FPM |
500 FPM |
IWG |
pa |
IWG |
pa |
IWG |
pa |
IWG |
pa |
IWG |
pa |
IWG |
pa |
Roughing Filters |
P20 |
0.02 |
5 |
0.03 |
7 |
0.04 |
10 |
0.06 |
15 |
0.11 |
27 |
0.17 |
42 |
P30 |
0.08 |
20 |
0.10 |
25 |
0.12 |
30 |
0.14 |
35 |
0.18 |
45 |
0.24 |
60 |
Intermediate Filters |
P60 |
0.09 |
22 |
0.12 |
30 |
0.15 |
37 |
0.18 |
45 |
0.24 |
60 |
0.30 |
75 |
P90 |
0.22 |
55 |
0.28 |
70 |
0.35 |
87 |
0.43 |
107 |
0.59 |
147 |
-- |
-- |
P95 |
0.27 |
67 |
0.33 |
82 |
0.40 |
100 |
0.48 |
120 |
0.64 |
159 |
-- |
-- |
P90 |
0.15 |
37 |
0.23 |
57 |
0.28 |
70 |
0.34 |
85 |
0.44 |
110 |
0.55 |
137 |
P95 |
0.25 |
62 |
0.33 |
82 |
0.38 |
95 |
0.44 |
110 |
0.54 |
134 |
0.65 |
162 |
HEPA Filters |
H95 |
0.28 |
70 |
0.36 |
90 |
0.45 |
112 |
0.55 |
137 |
0.75 |
187 |
1.00 |
249 |
H99.9 |
0.35 |
87 |
0.45 |
112 |
0.65 |
162 |
0.80 |
199 |
1.10 |
274 |
1.40 |
349 |
Media Modules |
MM-18 |
0.06 |
15 |
0.09 |
22 |
0.12 |
30 |
0.17 |
42 |
0.27 |
67 |
0.39 |
97 |
MM-12D |
0.40 |
100 |
0.65 |
162 |
0.85 |
212 |
-- |
-- |
-- |
-- |
-- |
-- |
NOTE: The pressure drops Indicated for MM-18/MM-12D modules are for CM-1000 media. When using CM-9000 media, multiply pressure drops shown by 1.25. |
☆ For more details, please CONTACT JUNE, or DOWN LOAD the PDF files. |
|
|
 |
|
|